{"id":3704,"date":"2026-02-26T16:55:39","date_gmt":"2026-02-26T13:55:39","guid":{"rendered":"https:\/\/wiki.dev.voka.io\/diseases\/uncategorized\/monitoramento-basico\/"},"modified":"2026-04-14T16:37:24","modified_gmt":"2026-04-14T13:37:24","slug":"monitoramento-basico","status":"publish","type":"diseases_post","link":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/","title":{"rendered":"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es e par\u00e2metros obrigat\u00f3rios de monitoramento"},"content":{"rendered":"<p><?xml encoding=\"UTF-8\" ?><\/p>\n<p>Monitoramento b\u00e1sico \u00e9 uma avalia\u00e7\u00e3o cont\u00ednua dos principais par\u00e2metros fisiol\u00f3gicos do corpo do paciente, permitindo a detec\u00e7\u00e3o oportuna de deteriora\u00e7\u00e3o na oxigena\u00e7\u00e3o, dist\u00farbios de ventila\u00e7\u00e3o, hemodin\u00e2mica, termorregula\u00e7\u00e3o e outras complica\u00e7\u00f5es potencialmente fatais durante a anestesia. <\/p>\n<p>As diretrizes internacionais enfatizam que a seguran\u00e7a do paciente na sala de opera\u00e7\u00f5es \u00e9 garantida n\u00e3o apenas pelo monitoramento, mas tamb\u00e9m pela presen\u00e7a constante e avalia\u00e7\u00e3o cl\u00ednica do anestesiologista durante a anestesia, procedimento de seda\u00e7\u00e3o e transporte do paciente, bem como alarmes de dispositivos de monitoramento devidamente ajustados.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp\" alt=\"Monitor de paciente com par\u00e2metros vitais b\u00e1sicos e avan\u00e7ados\"><figcaption class=\"wp-element-caption\">Monitor de paciente com par\u00e2metros vitais b\u00e1sicos e avan\u00e7ados<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\" id=\"controle-de-equipamentos-de-anestesiologia\">Controle de equipamentos de anestesiologia <\/h2>\n<p>O anestesiologista deve verificar todos os equipamentos antes do uso. O anestesiologista deve estar devidamente treinado para utilizar todos os equipamentos e realizar todas as verifica\u00e7\u00f5es especializadas recomendadas pelos fabricantes. <\/p>\n<p>O fornecimento, manuten\u00e7\u00e3o, calibra\u00e7\u00e3o e atualiza\u00e7\u00e3o dos equipamentos s\u00e3o de responsabilidade da institui\u00e7\u00e3o onde a anestesia \u00e9 realizada.<\/p>\n<p>Ao administrar qualquer componente da anestesia por meio de uma bomba de infus\u00e3o, o dispositivo deve ser verificado antes do uso. As bombas de infus\u00e3o devem ter alarmes sonoros ativados por padr\u00e3o.<\/p>\n<h3 class=\"wp-block-heading\" id=\"dispositivos-de-monitoramento\">Dispositivos de monitoramento <\/h3>\n<p>O monitoramento de um paciente sob qualquer tipo de anestesia deve incluir avalia\u00e7\u00e3o regular e registro de par\u00e2metros de oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o e circula\u00e7\u00e3o. <\/p>\n<p>O escopo espec\u00edfico do monitoramento \u00e9 determinado pela situa\u00e7\u00e3o cl\u00ednica e tipo de anestesia. Assim, o monitoramento m\u00ednimo durante a anestesia deve incluir v\u00e1rios componentes.<\/p>\n<p id=\"h-\u0432\u043e-\u0432\u0441\u0435\u0445-\u0441\u043b\u0443\u0447\u0430\u044f\u0445-nbsp\">Em todos os casos: <\/p>\n<ul class=\"wp-block-list\">\n<li>Ox\u00edmetro de pulso com pletismografia;<\/li>\n<li>Medi\u00e7\u00e3o n\u00e3o invasiva da press\u00e3o arterial;<\/li>\n<li>Eletrocardiografia (ECG);<\/li>\n<li>Medi\u00e7\u00e3o da temperatura antes da anestesia e a cada 30 minutos at\u00e9 o fim da cirurgia.<\/li>\n<\/ul>\n<p id=\"h-\u0432\u043e-\u0432\u0440\u0435\u043c\u044f-\u043e\u0431\u0449\u0435\u0439-\u0430\u043d\u0435\u0441\u0442\u0435\u0437\u0438\u0438-nbsp\">Durante a anestesia geral:<strong><\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>Concentra\u00e7\u00e3o de oxig\u00eanio no ar inalado e exalado; <\/li>\n<li>Capnografia com exibi\u00e7\u00e3o de onda.<\/li>\n<\/ul>\n<p>Dependendo da metodologia utilizada, deve-se implementar:<\/p>\n<ul class=\"wp-block-list\">\n<li>Concentra\u00e7\u00e3o de anest\u00e9sico inalat\u00f3rio e \u00f3xido nitroso no ar inalado e exalado quando usados;<\/li>\n<li>Press\u00e3o das vias a\u00e9reas, volume corrente e frequ\u00eancia respirat\u00f3ria durante ventila\u00e7\u00e3o mec\u00e2nica;<\/li>\n<li>Monitoramento neuromuscular quantitativo quando relaxantes musculares s\u00e3o usados, com alvo de monitoramento na sequ\u00eancia de quatro est\u00edmulos (TOF \u2013 Train of Four) \u2265 0,9 antes da extuba\u00e7\u00e3o;<\/li>\n<li>Eletroencefalografia processada (pEEG) ou monitoramento do \u00edndice bispectral (BIS) para anestesia intravenosa total;<\/li>\n<li>Monitoramento dos n\u00edveis de glicose no sangue capilar (deve estar dispon\u00edvel imediatamente).<\/li>\n<\/ul>\n<p id=\"h-\u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435-\u0444\u0438\u0437\u0438\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435-\u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b-\u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0435-\u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430-\u0432\u043e-\u0432\u0440\u0435\u043c\u044f-\u0430\u043d\u0435\u0441\u0442\u0435\u0437\u0438\u0438-\u043e\u043a\u0441\u0438\u0433\u0435\u043d\u0430\u0446\u0438\u044f-\u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u044f-\u043a\u0440\u043e\u0432\u043e\u043e\u0431\u0440\u0430\u0449\u0435\u043d\u0438\u0435-\u0438-\u0442\u0435\u0440\u043c\u043e\u0440\u0435\u0433\u0443\u043b\u044f\u0446\u0438\u044f-\u0431\u0443\u0434\u0443\u0442-\u0440\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0435\u043d\u044b-\u0431\u043e\u043b\u0435\u0435-\u043f\u043e\u0434\u0440\u043e\u0431\u043d\u043e\">Os principais par\u00e2metros fisiol\u00f3gicos que requerem monitoramento durante a anestesia (oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o, circula\u00e7\u00e3o e termorregula\u00e7\u00e3o) ser\u00e3o discutidos em mais detalhes.<\/p>\n<h2 class=\"wp-block-heading\" id=\"monitoramento-do-paciente\">Monitoramento do paciente<\/h2>\n<p>Durante a anestesia, o estado fisiol\u00f3gico do paciente e a adequa\u00e7\u00e3o da anestesia devem ser avaliados continuamente. Para este fim, dispositivos de monitoramento s\u00e3o usados para complementar a observa\u00e7\u00e3o cl\u00ednica. <\/p>\n<p>A observa\u00e7\u00e3o cl\u00ednica inclui: <\/p>\n<ul class=\"wp-block-list\">\n<li>Avalia\u00e7\u00e3o da cor das membranas mucosas; <\/li>\n<li>Tamanho da pupila, lacrimejamento, fotorrea\u00e7\u00e3o;<\/li>\n<li>Movimento do t\u00f3rax e\/ou bal\u00e3o respirat\u00f3rio;<\/li>\n<li>Aus\u00eancia de rea\u00e7\u00e3o a est\u00edmulos cir\u00fargicos;<\/li>\n<li>Palpa\u00e7\u00e3o do pulso; ausculta dos sons respirat\u00f3rios; <\/li>\n<li>Medi\u00e7\u00e3o da produ\u00e7\u00e3o de urina e perda sangu\u00ednea.<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\" id=\"monitoramento-da-oxigenacao\">Monitoramento da oxigena\u00e7\u00e3o<\/h3>\n<p>A avalia\u00e7\u00e3o da oxigena\u00e7\u00e3o \u00e9 realizada por meio da avalia\u00e7\u00e3o cl\u00ednica da cor da pele do paciente (embora este m\u00e9todo nem sempre seja confi\u00e1vel, devido a fatores como pigmenta\u00e7\u00e3o natural da pele, ilumina\u00e7\u00e3o do ambiente e concentra\u00e7\u00e3o de hemoglobina), oximetria de pulso cont\u00ednua (SpO\u2082) e determina\u00e7\u00e3o do teor de oxig\u00eanio na mistura inspirada.<\/p>\n<p>A oximetria de pulso \u00e9 um m\u00e9todo quantitativo de avalia\u00e7\u00e3o da oxigena\u00e7\u00e3o. Na sala de opera\u00e7\u00e3o, os ox\u00edmetros de pulso geralmente s\u00e3o colocados em um dedo ou l\u00f3bulo da orelha em adultos e no p\u00e9\/tornozelo ou pulso\/palma em lactentes, permitindo a passagem de luz pelos tecidos e registro do outro lado.<\/p>\n<p>Se a oximetria de pulso n\u00e3o puder ser usada durante a indu\u00e7\u00e3o da anestesia (por exemplo, em crian\u00e7as pequenas ou adultos n\u00e3o cooperativos), o monitor deve ser conectado imediatamente ap\u00f3s a perda de consci\u00eancia. O tom de pulso vari\u00e1vel e os sinais de alarme de limiar baixo devem ser aud\u00edveis para o anestesiologista. <\/p>\n<p>Durante toda anestesia geral com o uso de um aparelho de anestesia, \u00e9 obrigat\u00f3rio o uso de um analisador de oxig\u00eanio, prevenindo assim a entrega de uma mistura gasosa hip\u00f3xica. Analisadores de g\u00e1s contempor\u00e2neos para anestesia medem simultaneamente a concentra\u00e7\u00e3o de oxig\u00eanio (O\u2082), di\u00f3xido de carbono (CO\u2082) e anest\u00e9sico inalado.<\/p>\n<h3 class=\"wp-block-heading\" id=\"monitoramento-da-ventilacao\">Monitoramento da ventila\u00e7\u00e3o<\/h3>\n<p>Durante a anestesia, a adequa\u00e7\u00e3o da ventila\u00e7\u00e3o pulmonar precisa ser avaliada para todos os pacientes. Isso \u00e9 realizado atrav\u00e9s dos seguintes m\u00e9todos de observa\u00e7\u00e3o cl\u00ednica: <\/p>\n<ul class=\"wp-block-list\">\n<li>Monitoramento dos movimentos do t\u00f3rax; <\/li>\n<li>Ausculta; <\/li>\n<li>Monitoramento dos sinais de obstru\u00e7\u00e3o das vias a\u00e9reas em pacientes com respira\u00e7\u00e3o espont\u00e2nea. <\/li>\n<\/ul>\n<p>\u00c9 tamb\u00e9m necess\u00e1rio reconhecer prontamente sons respirat\u00f3rios anormais que podem surgir devido \u00e0 coloca\u00e7\u00e3o incorreta de dispositivos supra-gl\u00f3ticos, estridor, bloqueio das vias a\u00e9reas, laringoespasmo ou broncoespasmo.<\/p>\n<p>A capnografia (EtCO\u2082) \u00e9 um m\u00e9todo vital para monitorar a permeabilidade das vias a\u00e9reas e a ventila\u00e7\u00e3o alveolar. A capnografia de forma de onda \u00e9 o padr\u00e3o ouro para monitoramento das vias a\u00e9reas intubadas, pois confirma de forma confi\u00e1vel a intuba\u00e7\u00e3o traqueal correta e diagnostica broncoespasmo, hipoventila\u00e7\u00e3o e hipertermia maligna.<\/p>\n<p>A medi\u00e7\u00e3o da mec\u00e2nica pulmonar \u00e9 realizada por dispositivos de anestesia com ventila\u00e7\u00e3o, permitindo: <\/p>\n<ul class=\"wp-block-list\">\n<li>Monitoramento cont\u00ednuo do volume corrente, frequ\u00eancia respirat\u00f3ria e ventila\u00e7\u00e3o por minuto; <\/li>\n<li>Controle por meio do monitoramento de press\u00f5es de pico, m\u00e9dia e ao final da expira\u00e7\u00e3o nas vias a\u00e9reas em forma digital e de onda.<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\" id=\"monitoramento-do-sistema-circulatorio\">Monitoramento do sistema circulat\u00f3rio<\/h3>\n<p>A adequa\u00e7\u00e3o da fun\u00e7\u00e3o circulat\u00f3ria \u00e9 avaliada tanto por observa\u00e7\u00e3o cl\u00ednica quanto por monitores. A observa\u00e7\u00e3o cl\u00ednica \u00e9 realizada pela avalia\u00e7\u00e3o da cor e temperatura da pele, a qualidade dos pulsos palp\u00e1veis e ausculta dos sons card\u00edacos; a diurese pode ser utilizada para avaliar a perfus\u00e3o dos \u00f3rg\u00e3os.<\/p>\n<p>Um dispositivo padr\u00e3o para monitoramento intraoperat\u00f3rio n\u00e3o invasivo da PA \u00e9 uma bra\u00e7adeira oscilom\u00e9trica autom\u00e1tica, com medi\u00e7\u00f5es de PA realizadas periodicamente, geralmente n\u00e3o menos frequentemente que a cada 5 minutos.<\/p>\n<p>O ECG deve ser monitorado continuamente durante a anestesia. Este \u00e9 um m\u00e9todo confi\u00e1vel para monitorar a frequ\u00eancia card\u00edaca, ritmo, condu\u00e7\u00e3o e dist\u00farbios eletrol\u00edticos. O ECG de doze pontos de conex\u00e3o padr\u00e3o n\u00e3o \u00e9 vi\u00e1vel na sala de opera\u00e7\u00f5es. Em vez disso, s\u00e3o utilizadas tr\u00eas ou cinco pontos de conex\u00e3o.<\/p>\n<h3 class=\"wp-block-heading\" id=\"monitoramento-da-temperatura\">Monitoramento da temperatura<\/h3>\n<p>A maioria dos pacientes submetidos a anestesia geral por mais de 30 minutos ou cirurgias de grande porte com anestesia neuroaxial requer monitoramento da temperatura. <\/p>\n<p>A temperatura do paciente deve ser monitorada para detectar altera\u00e7\u00f5es (mais frequentemente hipotermia), manejar a termorregula\u00e7\u00e3o e detectar precocemente a hipertermia maligna.<\/p>\n<div class=\"social-banner-block\">\n<div class=\"social-banner-content\">\n<p class=\"h5-title text-black\">Encontra mais conte\u00fados cientificamente exactos nas nossas redes sociais<\/p>\n<p><span class=\"social-banner-text text-grey\">Subscreve e n\u00e3o percas os recursos mais recentes<\/span><\/p>\n<div class=\"social-links-wrapper\"><a class=\"social-icon-link\" href=\"https:\/\/www.facebook.com\/VOKA3DAnatomyAndPathology\/\" target=\"_blank\" rel=\"nofollow noopener\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/Social%20Icons\/facebook.svg\" alt=\"social link\"><\/a><a class=\"social-icon-link\" href=\"https:\/\/www.instagram.com\/voka.io\/\" target=\"_blank\" rel=\"nofollow noopener\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/Social%20Icons\/insta.svg\" alt=\"social link\"><\/a><a class=\"social-icon-link\" href=\"https:\/\/www.linkedin.com\/company\/voka-io\/posts\/?feedView=all\" target=\"_blank\" rel=\"nofollow noopener\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/Social%20Icons\/linkedin.svg\" alt=\"social link\"><\/a><a class=\"social-icon-link\" href=\"https:\/\/www.youtube.com\/@vokaio\" target=\"_blank\" rel=\"nofollow noopener\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/Social%20Icons\/youtube.svg\" alt=\"social link\"><\/a><a class=\"social-icon-link\" href=\"https:\/\/www.pinterest.com\/voka3danatomyandpathology\/\" target=\"_blank\" rel=\"nofollow noopener\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/Social%20Icons\/pinterest.svg\" alt=\"social link\"><\/a><a class=\"social-icon-link\" href=\"https:\/\/www.tiktok.com\/@voka.io\" target=\"_blank\" rel=\"nofollow noopener\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/Social%20Icons\/tiktok.svg\" alt=\"social link\"><\/a><a class=\"social-icon-link\" href=\"https:\/\/discord.gg\/7ejUpq8DRR\" target=\"_blank\" rel=\"nofollow noopener\"><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/Social%20Icons\/discord.svg\" alt=\"social link\"><\/a><\/div>\n<\/div>\n<p><img decoding=\"async\" class=\"social-banner-image\" loading=\"lazy\" src=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/common\/social-media-banner-mobile-image.webp\" alt=\"Banner background\"><\/div>\n<h2 class=\"wp-block-heading\" id=\"documentacao-da-anestesia\">Documenta\u00e7\u00e3o da anestesia<\/h2>\n<p>\u00c9 necess\u00e1rio registro preciso dos dados de todos os dispositivos de monitoramento. Atualmente, preferem-se sistemas eletr\u00f4nicos automatizados para manuten\u00e7\u00e3o da documenta\u00e7\u00e3o da anestesia, integrados ao prontu\u00e1rio m\u00e9dico eletr\u00f4nico do paciente. <\/p>\n<p>Os registros manuais de anestesia devem permitir o registro de FC, PA, SpO\u2082, EtCO\u2082 e EEG processado (se necess\u00e1rio) com frequ\u00eancia n\u00e3o inferior a cada 5 minutos, e outros par\u00e2metros com frequ\u00eancia n\u00e3o inferior a cada 15 minutos. <\/p>\n<p>Valores adicionais devem ser registrados se ocorrerem altera\u00e7\u00f5es significativas dentro desses intervalos. Em situa\u00e7\u00f5es de emerg\u00eancia, a manuten\u00e7\u00e3o de registros pode ser desafiadora; lacunas nas anota\u00e7\u00f5es devem ser preenchidas assim que a situa\u00e7\u00e3o cl\u00ednica permitir, utilizando dados de tend\u00eancias armazenados em dispositivos de monitoramento.<\/p>\n<div>\n<h2 class=\"faq-title h2-article\" id=\"faq\">FAQ<\/h2>\n<div class=\"faq-section\">\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">1. O que \u00e9 considerado monitoramento b\u00e1sico durante a anestesia?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">\u00c9 o conjunto m\u00ednimo de observa\u00e7\u00f5es e dispositivos para controlar a oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o, circula\u00e7\u00e3o e temperatura: SpO\u2082, ECG, press\u00e3o arterial (PA)\/frequ\u00eancia card\u00edaca (FC), avalia\u00e7\u00e3o da ventila\u00e7\u00e3o e capnografia para anestesia geral, controle do suprimento de oxig\u00eanio e monitoramento da temperatura conforme indicado.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">2. Por que a oximetria de pulso \u00e9 obrigat\u00f3ria para todos os pacientes?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">O SpO\u2082 \u00e9 a maneira mais r\u00e1pida de detectar hip\u00f3xia. Com alarmes adequados, ele permite a detec\u00e7\u00e3o de problemas antes do aparecimento de sinais cl\u00ednicos de cianose.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">3. Por que a capnografia \u00e9 necess\u00e1ria se o SpO\u2082 est\u00e1 normal?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">O SpO\u2082 pode permanecer normal com oxig\u00eanio suplementar mesmo em caso de hipoventila\u00e7\u00e3o ou apneia, enquanto a capnografia detecta imediatamente dist\u00farbios de ventila\u00e7\u00e3o, obstru\u00e7\u00f5es e desconex\u00f5es do circuito.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">4. Com que frequ\u00eancia a press\u00e3o arterial deve ser medida durante a anestesia geral?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">Na maioria dos padr\u00f5es, a PA \u00e9 medida por m\u00e9todo n\u00e3o invasivo (NIBP) e documentada regularmente, tipicamente em intervalos n\u00e3o inferiores a 5 minutos, a menos que as indica\u00e7\u00f5es exijam monitoramento mais frequente ou medi\u00e7\u00e3o invasiva da PA.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">5. Quais par\u00e2metros de alerta do monitor s\u00e3o mais importantes?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">Aqueles que alertam sobre amea\u00e7as \u00e0 oxigena\u00e7\u00e3o e ventila\u00e7\u00e3o: SpO\u2082, EtCO\u2082, apneia, alta press\u00e3o nas vias a\u00e9reas, limites cr\u00edticos de PA e FC.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">6. Todos os pacientes precisam de monitoramento da bloqueio neuromuscular (TOF)?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">N\u00e3o \u00e9 obrigat\u00f3rio para todos os pacientes, mas \u00e9 extremamente importante quando se utilizam agentes bloqueadores neuromusculares (BNM) para evitar relaxamento muscular residual e aumentar a seguran\u00e7a da extuba\u00e7\u00e3o.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">7. Quando \u00e9 essencial monitorar a temperatura?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">Para cirurgias prolongadas, em crian\u00e7as e idosos, durante grandes interven\u00e7\u00f5es abdominais\/ortop\u00e9dicas, exposi\u00e7\u00e3o significativa do corpo e durante aquecimento ativo, para evitar sobreaquecimento.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<div class=\"faq-item faq-answer-hidden\">\n<div class=\"question-block\">\n<div class=\"faq-question\">\n<p class=\" text-black h5-title\">8. Quais aspectos s\u00e3o frequentemente negligenciados no monitoramento b\u00e1sico?<\/p>\n<\/div>\n<div class=\"faq-answer text-main-text-color main-text-medium\">Continuidade da observa\u00e7\u00e3o durante as fases de indu\u00e7\u00e3o e despertar, monitoramento na sala de recupera\u00e7\u00e3o e unidade de cuidados intensivos\/durante o transporte, configura\u00e7\u00e3o adequada dos alarmes e interpreta\u00e7\u00e3o cl\u00ednica dos dados, n\u00e3o uma mera \u201cobserva\u00e7\u00e3o dos n\u00fameros\u201d.<\/div>\n<\/div>\n<div class=\"expand-button-wrapper\"><button class=\"text-accent expand-button\">+<\/button><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"sources-list-block sources-list-hidden\" id=\"referencias\">\n<div class=\"sources-list-content\">\n<div class=\"sources-list-title\">\n<p class=\"small-text-bold text-black sources-list-title-text\">Refer\u00eancias<\/p>\n<div class=\"sources-expand-button-wrapper-mobile\">\n<div class=\"sources-expand-button\"><svg width=\"32\" height=\"32\" viewbox=\"0 0 32 32\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 12L16 20L24 12\" stroke=\"#8C9AAB\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg><\/div>\n<\/div>\n<\/div>\n<div class=\"sources-list-items\">\n<div class=\"source-item\">\n<p class=\"main-text-semibold text-black\">1.<\/p>\n<div class=\"source-item-content\">\n<p class=\"main-text-semibold text-black\"><cite>VOKA 3D Anatomy & Pathology \u2013 Complete Anatomy and Pathology 3D Atlas (VOKA 3D Anatomia e Patologia \u2013 Atlas 3D completo de anatomia e patologia) [Internet]. VOKA 3D Anatomy & Pathology [VOKA 3D Anatomia & Patologia].<\/cite><\/p>\n<p><span class=\"small-text-medium text-grey\">Dispon\u00edvel em: https:\/\/catalog.voka.io\/<\/span><\/div>\n<\/div>\n<div class=\"source-item\">\n<p class=\"main-text-semibold text-black\">2.<\/p>\n<div class=\"source-item-content\">\n<p class=\"main-text-semibold text-black\"><cite>Klein, A.A., Meek, T., Allcock E. (2021). Recommendations for standards of monitoring during anaesthesia and recovery 2021: Guideline from the Association of Anaesthetists (Recomenda\u00e7\u00f5es para padr\u00f5es de monitoramento durante anestesia e recupera\u00e7\u00e3o 2021: Diretriz da Associa\u00e7\u00e3o de Anestesistas). Anaesthesia. 76(9):1212-1223. doi: 10.1111\/anae.15501.<\/cite><\/p>\n<\/div>\n<\/div>\n<div class=\"source-item\">\n<p class=\"main-text-semibold text-black\">3.<\/p>\n<div class=\"source-item-content\">\n<p class=\"main-text-semibold text-black\"><cite>Wollner, E., Nourian, M. M., Booth W. (2020). Impact of capnography on patient safety in high- and low-income settings: a scoping review (Efeito da capnografia na seguran\u00e7a do paciente em ambientes de alta e baixa renda: uma revis\u00e3o de escopo). British Journal of Anaesthesia. 125 (1): 88-103. 10.1016\/j.bja.2020.04.057.<\/cite><\/p>\n<\/div>\n<\/div>\n<div class=\"source-item\">\n<p class=\"main-text-semibold text-black\">4.<\/p>\n<div class=\"source-item-content\">\n<p class=\"main-text-semibold text-black\"><cite>Iohom G. Basic patient monitoring during anesthesia [Internet]. In: Post TW, editor. UpToDate [Internet]. Waltham (MA): UpToDate; 2026 [atualizado em 2 out. 2025; citado em fev. 2026].<\/cite><\/p>\n<p><span class=\"small-text-medium text-grey\">Dispon\u00edvel em: https:\/\/www.uptodate.com\/<\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"sources-expand-button-wrapper\">\n<div class=\"sources-expand-button\"><svg width=\"32\" height=\"32\" viewbox=\"0 0 32 32\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 12L16 20L24 12\" stroke=\"#8C9AAB\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Monitoramento b\u00e1sico \u00e9 uma avalia\u00e7\u00e3o cont\u00ednua dos principais par\u00e2metros fisiol\u00f3gicos do corpo do paciente, permitindo a detec\u00e7\u00e3o oportuna de deteriora\u00e7\u00e3o na oxigena\u00e7\u00e3o, dist\u00farbios de ventila\u00e7\u00e3o, hemodin\u00e2mica, termorregula\u00e7\u00e3o e outras complica\u00e7\u00f5es potencialmente fatais durante a anestesia. As diretrizes internacionais enfatizam que a seguran\u00e7a do paciente na sala de opera\u00e7\u00f5es \u00e9 garantida n\u00e3o apenas pelo monitoramento, mas [&hellip;]<\/p>\n","protected":false},"author":24,"featured_media":0,"template":"","diseases_category":[405],"class_list":["post-3704","diseases_post","type-diseases_post","status-publish","hentry","diseases_category-anestesiologia"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v26.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es, par\u00e2metros e seguran\u00e7a<\/title>\n<meta name=\"description\" content=\"An\u00e1lise dos padr\u00f5es de monitoramento b\u00e1sico durante a anestesia. Par\u00e2metros obrigat\u00f3rios de oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o e hemodin\u00e2mica para seguran\u00e7a do paciente.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es e par\u00e2metros obrigat\u00f3rios de monitoramento\" \/>\n<meta property=\"og:description\" content=\"An\u00e1lise dos padr\u00f5es de monitoramento b\u00e1sico durante a anestesia. Par\u00e2metros obrigat\u00f3rios de oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o e hemodin\u00e2mica para seguran\u00e7a do paciente.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/\" \/>\n<meta property=\"og:site_name\" content=\"Voka Wiki\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/VOKA3DAnatomyAndPathology\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-14T13:37:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/\"},\"author\":{\"name\":\"Irina K.\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/person\/8abe7f507baa40d8c9147b944cb9094e\"},\"headline\":\"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es e par\u00e2metros obrigat\u00f3rios de monitoramento\",\"datePublished\":\"2026-02-26T13:55:39+00:00\",\"dateModified\":\"2026-04-14T13:37:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/\"},\"wordCount\":1356,\"publisher\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#organization\"},\"image\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp\",\"inLanguage\":\"pt-PT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/\",\"url\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/\",\"name\":\"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es, par\u00e2metros e seguran\u00e7a\",\"isPartOf\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp\",\"datePublished\":\"2026-02-26T13:55:39+00:00\",\"dateModified\":\"2026-04-14T13:37:24+00:00\",\"description\":\"An\u00e1lise dos padr\u00f5es de monitoramento b\u00e1sico durante a anestesia. Par\u00e2metros obrigat\u00f3rios de oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o e hemodin\u00e2mica para seguran\u00e7a do paciente.\",\"breadcrumb\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage\",\"url\":\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp\",\"contentUrl\":\"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/wiki.dev.voka.io\/pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Anestesiologia\",\"item\":\"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es e par\u00e2metros obrigat\u00f3rios de monitoramento\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#website\",\"url\":\"https:\/\/wiki.dev.voka.io\/pt\/\",\"name\":\"Voka Wiki\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#organization\"},\"alternateName\":\"Anatomy & Pathology Wiki by VOKA\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/wiki.dev.voka.io\/pt\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#organization\",\"name\":\"Voka 3D Anatomy & Pathology\",\"alternateName\":\"VOKA\",\"url\":\"https:\/\/wiki.dev.voka.io\/pt\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/wiki.dev.voka.io\/wp-content\/uploads\/2025\/02\/cropped-voka-logo-1.png\",\"contentUrl\":\"https:\/\/wiki.dev.voka.io\/wp-content\/uploads\/2025\/02\/cropped-voka-logo-1.png\",\"width\":70,\"height\":16,\"caption\":\"Voka 3D Anatomy & Pathology\"},\"image\":{\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/VOKA3DAnatomyAndPathology\/\",\"https:\/\/www.instagram.com\/voka.io\/\",\"https:\/\/www.linkedin.com\/company\/voka-io\/\",\"https:\/\/www.youtube.com\/channel\/UCqGGuOEpr62ScH8Pjk2q5zw\/videos\",\"https:\/\/www.pinterest.com\/VokaAnatomyPro\/\",\"https:\/\/www.threads.com\/@voka.io\"],\"description\":\"VOKA.io offers 3D medical animations and custom 3D modeling services. Our product, VOKA 3D Anatomy & Pathology, is a digital atlas with over 1,000 detailed 3D models of human anatomy and pathology, designed for medical education, training, and patient communication.\",\"email\":\"info@voka.io\",\"telephone\":\"+1 814 351 4442\",\"legalName\":\"Voka 3D Anatomy & Pathology\",\"foundingDate\":\"2017-02-12\",\"naics\":\"541512\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"51\",\"maxValue\":\"200\"},\"publishingPrinciples\":\"https:\/\/wiki.voka.io\/pt\/principios-de-publicacao\/\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/person\/8abe7f507baa40d8c9147b944cb9094e\",\"name\":\"Irina K.\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8b5aba08f5c83f88cabee05be0283797befbbbb17f947d15ea39462f5443eac4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8b5aba08f5c83f88cabee05be0283797befbbbb17f947d15ea39462f5443eac4?s=96&d=mm&r=g\",\"caption\":\"Irina K.\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es, par\u00e2metros e seguran\u00e7a","description":"An\u00e1lise dos padr\u00f5es de monitoramento b\u00e1sico durante a anestesia. Par\u00e2metros obrigat\u00f3rios de oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o e hemodin\u00e2mica para seguran\u00e7a do paciente.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"pt_PT","og_type":"article","og_title":"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es e par\u00e2metros obrigat\u00f3rios de monitoramento","og_description":"An\u00e1lise dos padr\u00f5es de monitoramento b\u00e1sico durante a anestesia. Par\u00e2metros obrigat\u00f3rios de oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o e hemodin\u00e2mica para seguran\u00e7a do paciente.","og_url":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/","og_site_name":"Voka Wiki","article_publisher":"https:\/\/www.facebook.com\/VOKA3DAnatomyAndPathology\/","article_modified_time":"2026-04-14T13:37:24+00:00","og_image":[{"url":"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo estimado de leitura":"7 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#article","isPartOf":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/"},"author":{"name":"Irina K.","@id":"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/person\/8abe7f507baa40d8c9147b944cb9094e"},"headline":"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es e par\u00e2metros obrigat\u00f3rios de monitoramento","datePublished":"2026-02-26T13:55:39+00:00","dateModified":"2026-04-14T13:37:24+00:00","mainEntityOfPage":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/"},"wordCount":1356,"publisher":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/#organization"},"image":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage"},"thumbnailUrl":"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp","inLanguage":"pt-PT"},{"@type":"WebPage","@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/","url":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/","name":"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es, par\u00e2metros e seguran\u00e7a","isPartOf":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage"},"image":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage"},"thumbnailUrl":"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp","datePublished":"2026-02-26T13:55:39+00:00","dateModified":"2026-04-14T13:37:24+00:00","description":"An\u00e1lise dos padr\u00f5es de monitoramento b\u00e1sico durante a anestesia. Par\u00e2metros obrigat\u00f3rios de oxigena\u00e7\u00e3o, ventila\u00e7\u00e3o e hemodin\u00e2mica para seguran\u00e7a do paciente.","breadcrumb":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#primaryimage","url":"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp","contentUrl":"https:\/\/storage.googleapis.com\/dev_wiki_voka_io_303011\/articles\/en\/anesthesiology\/basic-anesthesia-monitoring\/patient-monitoring-basic-and-advanced-vital-signs.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/monitoramento-basico\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/wiki.dev.voka.io\/pt\/"},{"@type":"ListItem","position":2,"name":"Anestesiologia","item":"https:\/\/wiki.dev.voka.io\/pt\/doencas\/anestesiologia\/"},{"@type":"ListItem","position":3,"name":"Monitoramento b\u00e1sico durante a anestesia: padr\u00f5es e par\u00e2metros obrigat\u00f3rios de monitoramento"}]},{"@type":"WebSite","@id":"https:\/\/wiki.dev.voka.io\/pt\/#website","url":"https:\/\/wiki.dev.voka.io\/pt\/","name":"Voka Wiki","description":"","publisher":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/#organization"},"alternateName":"Anatomy & Pathology Wiki by VOKA","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wiki.dev.voka.io\/pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/wiki.dev.voka.io\/pt\/#organization","name":"Voka 3D Anatomy & Pathology","alternateName":"VOKA","url":"https:\/\/wiki.dev.voka.io\/pt\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/logo\/image\/","url":"https:\/\/wiki.dev.voka.io\/wp-content\/uploads\/2025\/02\/cropped-voka-logo-1.png","contentUrl":"https:\/\/wiki.dev.voka.io\/wp-content\/uploads\/2025\/02\/cropped-voka-logo-1.png","width":70,"height":16,"caption":"Voka 3D Anatomy & Pathology"},"image":{"@id":"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/VOKA3DAnatomyAndPathology\/","https:\/\/www.instagram.com\/voka.io\/","https:\/\/www.linkedin.com\/company\/voka-io\/","https:\/\/www.youtube.com\/channel\/UCqGGuOEpr62ScH8Pjk2q5zw\/videos","https:\/\/www.pinterest.com\/VokaAnatomyPro\/","https:\/\/www.threads.com\/@voka.io"],"description":"VOKA.io offers 3D medical animations and custom 3D modeling services. Our product, VOKA 3D Anatomy & Pathology, is a digital atlas with over 1,000 detailed 3D models of human anatomy and pathology, designed for medical education, training, and patient communication.","email":"info@voka.io","telephone":"+1 814 351 4442","legalName":"Voka 3D Anatomy & Pathology","foundingDate":"2017-02-12","naics":"541512","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"51","maxValue":"200"},"publishingPrinciples":"https:\/\/wiki.voka.io\/pt\/principios-de-publicacao\/"},{"@type":"Person","@id":"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/person\/8abe7f507baa40d8c9147b944cb9094e","name":"Irina K.","image":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/wiki.dev.voka.io\/pt\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8b5aba08f5c83f88cabee05be0283797befbbbb17f947d15ea39462f5443eac4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8b5aba08f5c83f88cabee05be0283797befbbbb17f947d15ea39462f5443eac4?s=96&d=mm&r=g","caption":"Irina K."}}]}},"_links":{"self":[{"href":"https:\/\/wiki.dev.voka.io\/pt\/wp-json\/wp\/v2\/diseases_post\/3704","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wiki.dev.voka.io\/pt\/wp-json\/wp\/v2\/diseases_post"}],"about":[{"href":"https:\/\/wiki.dev.voka.io\/pt\/wp-json\/wp\/v2\/types\/diseases_post"}],"author":[{"embeddable":true,"href":"https:\/\/wiki.dev.voka.io\/pt\/wp-json\/wp\/v2\/users\/24"}],"wp:attachment":[{"href":"https:\/\/wiki.dev.voka.io\/pt\/wp-json\/wp\/v2\/media?parent=3704"}],"wp:term":[{"taxonomy":"diseases_category","embeddable":true,"href":"https:\/\/wiki.dev.voka.io\/pt\/wp-json\/wp\/v2\/diseases_category?post=3704"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}